| News Headlines |
Sun. May 16th 2010 Charter Member Passes Away
John Lemonovich was a
life member and one of
six founding fathers of
the Richeyville Vol Fire
Co passed away on Sunday
May 16...
Read more »
|
Wed. Sep 2nd 2009 Cook Books For Sale
The Richeyville VFC has
cook books for sale at a
cost of $12.00
each. They make
great gifts for family
and friends.&nbs...
Read more »
|
Sun. May 10th 2009 Bike Ride Tee Shirts
2007 & 2008 Bike Ride
Tee Shirts are availible
at the firehall for $3.00
each. Sizes vary
Read more »
|
| Apparatus Gallery |  |
| Contact Information |
Richeyville Volunteer Fire Company Inc
14 Firehall Rd
Richeyville, PA 15358
Non-Emergency: 724-632-6390
Emergency: 911
Fax: 724-632-3273
Contact Us Driving Directions Map
|
|
Fire Glossary Print this page
Page: |
1 |
2 |
Palmer drought severity index (PDI) Technique for measuring impact of soil moisture changes on vegetation, for predicting fire danger and fire behavior.
Panic doors, panic hardware Fire safety appliance permitting locked doors (typically self-closing) to be opened from the inside when pressed with sufficient force, thus permitting a person to open the door without having to turn a knob or lever.
Parallel attack Fire containment method where crews constructs fireline at some distance from the edge of the fire (e.g., 100 yards) and then burn out the fuel in the buffer as the fireline is completed.
PASS device, personal alert safety system An alarm device which signals that a firefighter is in trouble. It can be activated manually by the firefighter, or activates automatically if the firefighter stops moving. May be integral to SCBA or separately activated.
Passport (accountability) System in which each firefighter has an identification document that is collected by the person in charge of accounting for the current location of the respective individuals, and returned to the firefighter when he or she leaves the dangerous area.
Perennial grasses An extremely volatile fuel, after curing, in May, June, July, which can lead to large, fast fires that may reach larger fuels.
Personal alert safety system See PASS device in Glossary of firefighting equipment.
Personnel accountability report End-result of personnel accountability system. Best report is all hands, AOK worst is squad missing.
Personnel accountability system Tag, 'passport', or other system for identification and tracking of personnel at an incident, especially those entering and leaving an IDLH area; intended to permit rapid determination of who may be at risk or lost during sudden changes at the scene.
Pickheaded axe Standard fire axe having a 6 or 8 pound (2.7 to 3.6 kg) steel head with a cutting blade on one edge and a square, pointed pick on the opposite side. Come in various handle lengths.
Pike pole See Hook.
Platoon A subdivision of a fire company, led a fire officer of either the rank captain or lieutenant, such that one of several platoons is assigned to duty for a specified period. Also called a watch".
Plec-Tron Jargon, brand-name of early radio-frequency paging system for summoning firefighters.
Point of origin An element of fire behavior, indicating where a fire began, supporting further analysis of where the fire went or will go; evidence of specific origin is often obscured or destroyed by suppression tactics.
Pompier ladder: A style of ladder that is also known as a Scaling Ladder". It is used to climb from one window to another. It differs from other ladders in that it does not rest on the ground it instead uses a large hook at the top to attach to a window sill. The word "Pompier" is French for fireman.
Portable water tank Collapsible reservoir used for storing water transported to fireground by tanker. May be inflatable or supported by a frame.
Positive pressure Pressure at higher than atmospheric; used in SCBA facepieces and in smoke-proof stairwells to reduce entry of smoke or fumes through small openings.
Positive Pressure Ventilation (PPV) Ventilation of an area by the use of a fan to push clean air into that space and controlled use of openings for the escape of smoke and gasses.
Post indicator valve (PIV) A type of valve used for underground sprinkler shutoff, having a lockable actuator atop a post with a window indicating open" or "shut" status of the valve.
Pre-fire, pre-incident planning Information collected by fire prevention officers to assist in identifying hazards and the equipment, supplies, personnel, skills, and procedures needed to deal with a potential incident.
|
|
| Executive Officers |
President - Brian Lynch
Vice President - Tom Hill
Secretary - Chris Pohill
Treasurer - Gary Gizzi
Assistant Treasurer - Dave Sheets
Chaplin - Patty Hagedorn
Assistant Chaplin - Owen Bercosky
|
| Line Officers |
Chief 27 - Dave Pohill
Chief 27-1 - Dave Sheets
Chief 27-2 - George Hagedorn Jr.
Captain 27 - Chris Pohill
Captain 27-2 - Jason Wolpink
Lieutenant 27-1 - Gary Gizzi
Lieutenant 27-2 - Brian Lynch
|
| Upcoming Events | Every Sun. 5:00pm Bingo
|
| Picture Gallery |  |
| 2010 Call Volume |
| |
Fire |
EMS |
| January |
12 |
8 |
| February |
38 |
7 |
| March |
20 |
7 |
| April |
13 |
7 |
| May |
23 |
3 |
| June |
20 |
7 |
| July |
10 |
8 |
| August |
15 |
3 |
| September |
|
|
| October |
|
|
| November |
|
|
| December |
|
|
| Total |
151 | 50 |
View Call Volume History
|
|